Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Opt Express ; 30(22): 40277-40291, 2022 Oct 24.
Article in English | MEDLINE | ID: covidwho-2089309

ABSTRACT

We conceptualized and numerically investigated a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor for rapid detection and quantification of novel coronavirus. The plasmonic gold-based optical sensor permits three different ways to quantify the virus concentrations inside patient's body based on different ligand-analyte conjugate pairs. This photonic biosensor demonstrates viable detections of SARS-CoV-2 spike receptor-binding-domain (RBD), mutated viral single-stranded ribonucleic acid (RNA) and human monoclonal antibody immunoglobulin G (IgG). A marquise-shaped core is introduced to facilitate efficient light-tailoring. Analytes are dissolved in sterile phosphate buffered saline (PBS) and surfaced on the plasmonic metal layer for realizing detection. The 1-pyrene butyric acid n-hydroxy-succinimide ester is numerically used to immobilize the analytes on the sensing interface. Using the finite element method (FEM), the proposed sensor is studied critically and optimized for the refractive index (RI) range from 1.3348-1.3576, since the target analytes RIs fluctuate within this range depending on the severity of the viral infection. The polarization-dependent sensor exhibits dominant sensing attributes for x-polarized mode, where it shows the average wavelength sensitivities of 2,009 nm/RIU, 2,745 nm/RIU and 1,984 nm/RIU for analytes: spike RBD, extracted coronavirus RNA and antibody IgG, respectively. The corresponding median amplitude sensitivities are 135 RIU-1, 196 RIU-1 and 140 RIU-1, respectively. The maximum sensor resolution and figure of merit are found 2.53 × 10-5 RIU and 101 RIU-1, respectively for viral RNA detection. Also, a significant limit of detection (LOD) of 6.42 × 10-9 RIU2/nm is obtained. Considering modern bioassays, the proposed compact photonic sensor will be well-suited for rapid point-of-care COVID testing.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , SARS-CoV-2 , Ligands , Butyric Acid , COVID-19 Testing , RNA, Viral , COVID-19/diagnosis , Gold/chemistry , Immunoglobulin G , Succinimides , Pyrenes , Antibodies, Monoclonal , Esters , Phosphates
2.
J Clin Lab Anal ; 35(12): e24091, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1499275

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly infectious and concealed virus that causes pneumonia, severe acute respiratory syndrome, and even death. Although the epidemic has been controlled since the development of vaccines and quarantine measures, many people are still infected, particularly in third-world countries. Several methods have been developed for detection of SARS-CoV-2, but owing to its price and efficiency, the immune strip could be a better method for the third-world countries. METHODS: In this study, two antibodies were linked to latex microspheres, using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide, as the bridge to decrease the cost further and improve the detection performance. The specificity of the lateral flow immunoassay strip (LFIA) was tested by several common viruses and respiratory bacterial infections. Besides, the reproducibility and stability of the LFIAs were tested on the same batch of test strips. Under optimal conditions, the sensitivity of LFIA was determined by testing different dilutions of the positive specimens. RESULTS: The proposed LFIAs were highly specific, and the limit of detection was as low as 25 ng/mL for SARS-CoV-2 antigens. The clinical applicability was evaluated with 659 samples (230 positive and 429 negative samples) by using both LFIA and rRT-PCR. Youden's index (J) was used to assess the performance of these diagnostic tests. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. In addition, the consistency of our proposed LFIA was analyzed using Cohen's kappa coefficient (κ = 0.9620). CONCLUSION: We found disease stage, age, gender, and clinical manifestations have only a slight influence on the diagnosis. Therefore, the lateral flow immunoassay SARS-CoV-2 antigen test strip is suitable for point-of-care detection and provides a great application for SARS-CoV-2 epidemic control in the third-world countries.


Subject(s)
Antigens, Viral/analysis , COVID-19 Serological Testing/methods , Immunoassay/methods , COVID-19 Serological Testing/instrumentation , Carbodiimides/chemistry , Humans , Immunoassay/instrumentation , Latex/chemistry , Methylamines/chemistry , Microscopy, Electron, Scanning , Microspheres , Point-of-Care Systems , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/immunology , Sensitivity and Specificity , Succinimides/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL